Merge pull request #344 from amec0e/main

Multiple New additions for NFC, Infrared and Subghz
This commit is contained in:
UberGuidoZ 2023-02-21 10:28:30 -08:00 committed by GitHub
commit 494a55560d
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
8 changed files with 146 additions and 10 deletions

View File

@ -1,7 +1,7 @@
Filetype: IR library file
Version: 1
# Last Updated 13th Jan, 2023
# Last Checked 8th Feb, 2023
# Last Updated 21st Feb, 2023
# Last Checked 21st Feb, 2023
#
name: POWER
type: raw
@ -1542,3 +1542,33 @@ type: raw
frequency: 38000
duty_cycle: 0.330000
data: 3110 1567 551 1031 550 356 471 1032 550 356 471 356 445 1084 497 355 472 357 497 356 472 1058 523 1058 523 356 471 356 470 357 469 357 470 357 474 357 470 1063 519 357 470 1063 518 1063 519 1063 518 357 470 357 471
#
name: POWER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 3087 1607 488 1064 517 335 492 1087 484 315 512 340 487 1091 490 336 491 338 489 1089 492 333 494 332 485 341 486 340 487 338 489 336 491 339 488 1090 491 334 493 1085 486 340 487 1091 490 1088 493 333 484 343 484 44227 178
#
name: TIMER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 3092 1602 492 1059 512 341 486 1092 489 337 490 336 491 1087 494 332 485 344 493 1085 486 1093 488 1064 517 1061 520 333 494 332 484 341 486 343 484 1094 487 1091 490 336 491 335 492 334 493 333 484 1094 487 340 487
#
name: POWER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 8838 3941 624 1427 514 500 515 497 541 473 540 1487 540 474 539 474 538 476 512 1538 514 1516 544 466 514 497 514 501 514 499 514 500 513 499 513 501 487 525 514 499 512 502 487 526 512 1517 542 470 487 1539 513 499 512 503 513 499 512 1513 512
#
name: POWER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 8364 4223 621 1958 1115 1478 593 1986 1082 1566 1072 1497 576 2003 1069 1513 1069 1541 1070 1505 1069 1505 1069 1497 1070 1550 1069 1530 1045 1522 551 2028 1045 1582 1044 1530 1044 1522 1045 1530 1044 1566 1045 1530 1045 1530 550 2021 550 2064 1044 1530 1044 1523 1043 1531 1044 1566 1045 1531 1043 1531 1044 1523 1044 1575 1043 1531 1044 1523 1044 1531 1044 1567 1044 1531 1043 1531 1044 1524 1043 1575 1043 1532 1043 1524 1043 1532 1043 1568 1042 1532 1043 1532 1043 1524 1043 1576 1042 1532 1043 1524 1043 1532 1042 1569 1042 1533 1016 1558 1042 1525 1042 1577 1016 1558 523 2048 1042 1525 547 2071 1041 1533 523 2049 522 2049 522
#
name: MODE
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 8362 4223 595 1983 1116 1480 592 1987 1081 1567 1070 1524 550 2029 1043 1540 1042 1568 1043 1532 549 2030 1042 1540 1042 1568 1042 1532 1042 1532 549 2022 549 2065 1043 1528 1043 1532 1043 1524 1042 1576 1042 1532 1042 1525 548 2030 549 2082 1042 1524 1042 1533 1042 1525 1042 1576 1042 1533 1042 1525 1041 1533 1042 1569 1042 1533 1042 1533 1042 1525 1041 1577 1041 1533 1042 1525 1041 1534 1041 1569 1042 1533 1041 1534 1040 1526 1041 1578 1041 1534 1041 1526 1040 1534 1041 1570 1041 1534 1015 1560 1015 1552 1015 1604 1040 1535 1040 1527 1039 1535 1014 1597 1013 1561 1014 1561 1013 1554 519 2129 987 1554 544 2036 518 2093 987

View File

@ -1,7 +1,7 @@
Filetype: IR library file
Version: 1
# Last Updated 8th Feb, 2023
# Last Checked 8th Feb, 2023
# Last Updated 21st Feb, 2023
# Last Checked 21st Feb, 2023
#
name: POWER
type: parsed
@ -2050,3 +2050,45 @@ type: parsed
protocol: NEC
address: 01 00 00 00
command: 10 00 00 00
#
name: POWER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 4555 4463 532 473 532 473 531 474 530 474 530 1478 531 1478 531 475 529 476 528 1482 551 1480 529 1480 528 1481 528 477 527 478 527 478 526 478 527 4498 526 477 527 477 527 478 526 478 526 478 526 478 526 478 527 478 526 1483 527 1483 526 1483 526 478 526 1483 527 1483 527 1483 526 1483 526 478 526 478 527 478 527 1484 526 55527 4527 4492 526 478 526 478 526 478 526 479 526 1483 527 1483 526 478 526 478 526 1483 527 1483 526 1483 526 1483 526 478 527 478 526 479 526 478 526 4497 526 478 526 478 526 478 526 478 526 478 526 478 526 478 526 478 526 1484 525 1483 526 1484 525 478 526 1484 525 1484 525 1484 525 1484 525 478 526 479 526 479 525 1484 525
#
name: VOL+
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 4552 4463 531 474 530 474 530 474 530 474 530 1478 531 1478 531 475 529 476 553 1455 554 1478 530 1479 529 1481 527 477 527 478 526 478 526 478 526 4497 526 478 526 478 526 478 526 477 527 1483 526 1482 527 1482 527 478 526 1483 526 1483 526 1483 526 478 526 478 526 478 526 478 526 1483 526 478 526 478 526 478 526 1483 526
#
name: VOL-
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 325 50440 173 137541 4551 4465 530 475 529 475 529 474 530 474 530 1479 530 1479 529 476 528 477 527 1480 554 1457 551 1480 528 1481 527 477 527 478 526 478 526 478 526 4497 525 478 526 478 526 478 526 478 526 479 525 479 525 479 525 1484 525 1483 526 1484 525 1483 526 479 525 1483 526 1483 526 1483 526 479 525 479 525 479 525 479 525 1484 525
#
name: POWER
type: parsed
protocol: NECext
address: 30 FC 00 00
command: 10 EF 00 00
#
name: MUTE
type: parsed
protocol: NECext
address: 30 FC 00 00
command: 0C F3 00 00
#
name: VOL+
type: parsed
protocol: NECext
address: 30 FC 00 00
command: 0D F2 00 00
#
name: VOL-
type: parsed
protocol: NECext
address: 30 FC 00 00
command: 17 E8 00 00

View File

@ -1,7 +1,7 @@
Filetype: IR library file
Version: 1
# Last Updated 8th Feb, 2023
# Last Checked 8th Feb, 2023
# Last Updated 15th Feb, 2023
# Last Checked 21st Feb, 2023
#
name: POWER
type: raw
@ -1401,3 +1401,21 @@ type: parsed
protocol: NEC
address: 01 00 00 00
command: 0D 00 00 00
#
name: POWER
type: parsed
protocol: NECext
address: 80 DE 00 00
command: 00 FF 00 00
#
name: SPEED+
type: parsed
protocol: NECext
address: 80 DE 00 00
command: 08 F7 00 00
#
name: SPEED-
type: parsed
protocol: NECext
address: 80 DE 00 00
command: 10 EF 00 00

View File

@ -1,7 +1,7 @@
Filetype: IR library file
Version: 1
# Last Updated 8th Feb, 2023
# Last Checked 8th Feb, 2023
# Last Updated 21st Feb, 2023
# Last Checked 21st Feb, 2023
#
# ON
name: POWER
@ -838,3 +838,9 @@ type: parsed
protocol: NECext
address: 87 45 00 00
command: 52 AD 00 00
#
name: POWER
type: raw
frequency: 38000
duty_cycle: 0.330000
data: 8811 4222 530 1580 531 1579 531 507 531 507 531 507 531 508 531 508 530 1582 528 1583 527 535 503 1608 502 536 501 1609 501 537 501 1610 500 538 500 1611 499 538 500 539 500 538 500 1611 500 539 499 538 500 1611 499 539 499 1611 499 1611 500 1611 499 539 499 1611 500 1611 500 539 499 35437 8784 4252 500 1611 500 1612 500 539 500 539 500 539 500 539 500 539 500 1611 500 1612 499 539 500 1612 500 539 500 1612 499 539 500 1612 500 539 500 1612 499 539 500 539 500 539 499 1612 499 540 499 539 500 1612 499 539 500 1612 499 1613 499 1612 499 539 500 1612 500 1612 500 539 500

View File

@ -1,7 +1,7 @@
Filetype: IR library file
Version: 1
# Last Updated 19th Jan, 2023
# Last Checked 8th Feb, 2023
# Last Updated 15th Feb, 2023
# Last Checked 21st Feb, 2023
#
name: POWER
type: parsed
@ -1839,3 +1839,27 @@ type: parsed
protocol: SIRC20
address: 5A 0E 00 00
command: 11 00 00 00
#
name: VOL+
type: parsed
protocol: RC5
address: 00 00 00 00
command: 15 00 00 00
#
name: VOL-
type: parsed
protocol: RC5
address: 00 00 00 00
command: 14 00 00 00
#
name: CH+
type: parsed
protocol: RC5
address: 00 00 00 00
command: 18 00 00 00
#
name: CH-
type: parsed
protocol: RC5
address: 00 00 00 00
command: 17 00 00 00

Binary file not shown.

View File

@ -0,0 +1,8 @@
Filetype: Flipper SubGhz Key File
Version: 1
Frequency: 433920000
Preset: FuriHalSubGhzPresetOok650Async
Protocol: KeeLoq
Bit: 64
Key: 8D 95 18 A7 38 48 ED 42
Manufacture: Elmes_Poland

View File

@ -0,0 +1,8 @@
Filetype: Flipper SubGhz Key File
Version: 1
Frequency: 433920000
Preset: FuriHalSubGhzPresetOok650Async
Protocol: KeeLoq
Bit: 64
Key: DA 8F F0 43 38 48 ED 44
Manufacture: Elmes_Poland