Filetype: IR library file Version: 1 # Last Updated 28th Dec, 2022 # Last Checked 28th Dec, 2022 # # Sony KDL40RD453 # name: POWER type: raw frequency: 38000 duty_cycle: 0.33 data: 2445 582 1221 603 548 602 1191 609 572 602 1191 609 542 607 544 631 1172 603 568 606 545 605 566 608 543 26263 2414 611 1192 607 544 606 1197 602 569 606 1197 602 539 611 540 635 1168 606 565 610 541 608 563 587 564 # name: POWER type: parsed protocol: NEC address: 04 00 00 00 command: 40 00 00 00 # name: MUTE type: parsed protocol: NEC address: 04 00 00 00 command: 12 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 7F 00 00 command: 15 EA 00 00 # name: MUTE type: parsed protocol: NECext address: 00 7F 00 00 command: 16 E9 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 7F 00 00 command: 1B E4 00 00 # name: VOL- type: parsed protocol: NECext address: 00 7F 00 00 command: 1A E5 00 00 # name: CH+ type: parsed protocol: NECext address: 00 7F 00 00 command: 19 E6 00 00 # name: CH- type: parsed protocol: NECext address: 00 7F 00 00 command: 18 E7 00 00 # name: POWER type: parsed protocol: Kaseikyo address: 80 02 20 00 command: D0 03 00 00 # name: MUTE type: parsed protocol: Kaseikyo address: 80 02 20 00 command: 20 03 00 00 # name: VOL+ type: parsed protocol: Kaseikyo address: 80 02 20 00 command: 00 02 00 00 # name: VOL- type: parsed protocol: Kaseikyo address: 80 02 20 00 command: 10 02 00 00 # name: CH+ type: parsed protocol: Kaseikyo address: 80 02 20 00 command: 40 03 00 00 # name: CH- type: parsed protocol: Kaseikyo address: 80 02 20 00 command: 50 03 00 00 # name: MUTE type: parsed protocol: NECext address: 00 FB 00 00 command: 0F F0 00 00 # name: POWER type: parsed protocol: NECext address: 00 FB 00 00 command: 0A F5 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 FB 00 00 command: 58 A7 00 00 # name: VOL- type: parsed protocol: NECext address: 00 FB 00 00 command: 4B B4 00 00 # name: CH+ type: parsed protocol: NECext address: 00 FB 00 00 command: 1F E0 00 00 # name: CH- type: parsed protocol: NECext address: 00 FB 00 00 command: 1E E1 00 00 # name: POWER type: parsed protocol: NECext address: 00 DF 00 00 command: 1C E3 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 DF 00 00 command: 4B B4 00 00 # name: VOL- type: parsed protocol: NECext address: 00 DF 00 00 command: 4F B0 00 00 # name: MUTE type: parsed protocol: NECext address: 00 DF 00 00 command: 08 F7 00 00 # name: CH+ type: parsed protocol: NECext address: 00 DF 00 00 command: 09 F6 00 00 # name: CH- type: parsed protocol: NECext address: 00 DF 00 00 command: 05 FA 00 00 # name: POWER type: parsed protocol: NEC address: 01 00 00 00 command: 03 00 00 00 # name: CH+ type: parsed protocol: RC5 address: 00 00 00 00 command: 20 00 00 00 # name: CH- type: parsed protocol: RC5 address: 00 00 00 00 command: 21 00 00 00 # name: VOL- type: parsed protocol: RC5 address: 00 00 00 00 command: 11 00 00 00 # name: VOL+ type: parsed protocol: RC5 address: 00 00 00 00 command: 10 00 00 00 # name: POWER type: parsed protocol: NEC address: 03 00 00 00 command: 1D 00 00 00 # name: MUTE type: parsed protocol: NECext address: 00 7F 00 00 command: 4E B1 00 00 # name: VOL+ type: parsed protocol: NEC address: 03 00 00 00 command: 11 00 00 00 # name: VOL- type: parsed protocol: NEC address: 03 00 00 00 command: 15 00 00 00 # name: POWER type: parsed protocol: NEC address: 19 00 00 00 command: 18 00 00 00 # name: MUTE type: parsed protocol: NEC address: 19 00 00 00 command: 56 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 19 00 00 00 command: 4F 00 00 00 # name: VOL- type: parsed protocol: NEC address: 19 00 00 00 command: 0D 00 00 00 # name: CH+ type: parsed protocol: NEC address: 19 00 00 00 command: 4C 00 00 00 # name: CH- type: parsed protocol: NEC address: 19 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: NECext address: BA A0 00 00 command: 4C B3 00 00 # name: MUTE type: parsed protocol: NECext address: BA A0 00 00 command: 01 FE 00 00 # name: POWER type: parsed protocol: NECext address: AD ED 00 00 command: B5 4A 00 00 # # ON name: POWER type: parsed protocol: NEC address: 01 00 00 00 command: 40 00 00 00 # ON name: POWER type: parsed protocol: NECext address: A0 B7 00 00 command: E9 16 00 00 # name: POWER type: parsed protocol: SIRC address: 01 00 00 00 command: 15 00 00 00 # name: POWER type: parsed protocol: SIRC address: 10 00 00 00 command: 15 00 00 00 # name: POWER type: parsed protocol: NEC address: 08 00 00 00 command: 05 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 08 00 00 00 command: 00 00 00 00 # name: VOL- type: parsed protocol: NEC address: 08 00 00 00 command: 01 00 00 00 # name: CH+ type: parsed protocol: NEC address: 08 00 00 00 command: 02 00 00 00 # name: CH- type: parsed protocol: NEC address: 08 00 00 00 command: 03 00 00 00 # name: MUTE type: parsed protocol: NEC address: 08 00 00 00 command: 0B 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 DF 00 00 command: 1C 00 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 DF 00 00 command: 4B 00 00 00 # name: VOL- type: parsed protocol: NECext address: 00 DF 00 00 command: 4F 00 00 00 # name: CH+ type: parsed protocol: NECext address: 00 DF 00 00 command: 09 00 00 00 # name: CH- type: parsed protocol: NECext address: 00 DF 00 00 command: 05 00 00 00 # name: MUTE type: parsed protocol: NECext address: 00 DF 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 0C 00 00 00 # name: MUTE type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 0D 00 00 00 # name: VOL+ type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 14 00 00 00 # name: VOL- type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 15 00 00 00 # name: CH+ type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 12 00 00 00 # name: CH- type: parsed protocol: Samsung32 address: 0E 00 00 00 command: 13 00 00 00 # name: POWER type: parsed protocol: RC6 address: 00 00 00 00 command: 0C 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 07 00 00 00 command: 02 00 00 00 # name: POWER type: parsed protocol: NEC address: 50 00 00 00 command: 17 00 00 00 # name: POWER type: parsed protocol: NEC address: 40 00 00 00 command: 12 00 00 00 # name: POWER type: parsed protocol: NECext address: 31 49 00 00 command: 63 00 00 00 # name: POWER type: parsed protocol: NEC address: AA 00 00 00 command: 1C 00 00 00 # name: POWER type: parsed protocol: NEC address: 38 00 00 00 command: 1C 00 00 00 # name: POWER type: parsed protocol: NECext address: 83 7A 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: NEC address: 53 00 00 00 command: 17 00 00 00 # name: POWER type: parsed protocol: NECext address: 18 18 00 00 command: C0 00 00 00 # name: POWER type: parsed protocol: NEC address: 38 00 00 00 command: 10 00 00 00 # name: POWER type: parsed protocol: NEC address: AA 00 00 00 command: C5 00 00 00 # name: POWER type: parsed protocol: NEC address: 04 00 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: NEC address: 18 00 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: NEC address: 71 00 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 6F 00 00 command: 0A 00 00 00 # name: POWER type: parsed protocol: NEC address: 48 00 00 00 command: 00 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 7B 00 00 command: 13 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 7E 00 00 command: 18 00 00 00 # name: POWER type: parsed protocol: NEC address: 50 00 00 00 command: 08 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 75 00 00 command: 0A 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 57 00 00 command: 0A 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 0B 00 00 00 command: 0A 00 00 00 # name: POWER type: parsed protocol: NEC address: AA 00 00 00 command: 1B 00 00 00 # name: POWER type: parsed protocol: NECext address: 85 46 00 00 command: 12 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 05 00 00 00 command: 02 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 08 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: NEC address: 00 00 00 00 command: 01 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 07 00 00 00 command: E6 00 00 00 # name: VOL+ type: parsed protocol: Samsung32 address: 07 00 00 00 command: 07 00 00 00 # name: VOL- type: parsed protocol: Samsung32 address: 07 00 00 00 command: 0B 00 00 00 # name: CH+ type: parsed protocol: Samsung32 address: 07 00 00 00 command: 12 00 00 00 # name: CH- type: parsed protocol: Samsung32 address: 07 00 00 00 command: 10 00 00 00 # name: MUTE type: parsed protocol: Samsung32 address: 07 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: NEC address: 71 00 00 00 command: 4A 00 00 00 # name: POWER type: parsed protocol: NEC address: 60 00 00 00 command: 03 00 00 00 # name: POWER type: parsed protocol: NEC address: 60 00 00 00 command: 00 00 00 00 # name: POWER type: parsed protocol: NEC address: 42 00 00 00 command: 01 00 00 00 # name: POWER type: parsed protocol: NECext address: 50 AD 00 00 command: 00 00 00 00 # name: POWER type: parsed protocol: NECext address: 50 AD 00 00 command: 02 00 00 00 # name: POWER type: parsed protocol: NEC address: 50 00 00 00 command: 3F 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 06 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: NEC address: 08 00 00 00 command: 12 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 08 00 00 00 command: 0B 00 00 00 # name: POWER type: parsed protocol: NECext address: 83 55 00 00 command: C2 00 00 00 # name: POWER type: parsed protocol: NEC address: 00 00 00 00 command: 51 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 BD 00 00 command: 01 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 00 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 16 00 00 00 command: 0F 00 00 00 # name: POWER type: parsed protocol: NEC address: 01 00 00 00 command: 01 00 00 00 # name: POWER type: parsed protocol: NECext address: 80 68 00 00 command: 49 00 00 00 # name: POWER type: parsed protocol: NECext address: 86 02 00 00 command: 49 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 7F 00 00 command: 0A F5 00 00 # name: POWER type: parsed protocol: NECext address: 01 72 00 00 command: 1E E1 00 00 # name: CH+ type: parsed protocol: NECext address: 01 72 00 00 command: 48 B7 00 00 # name: CH- type: parsed protocol: NECext address: 01 72 00 00 command: 44 BB 00 00 # name: VOL+ type: parsed protocol: NECext address: 01 72 00 00 command: 0A F5 00 00 # name: VOL- type: parsed protocol: NECext address: 01 72 00 00 command: 06 F9 00 00 # name: MUTE type: parsed protocol: NECext address: 01 72 00 00 command: 5C A3 00 00 # name: POWER type: parsed protocol: NECext address: 86 05 00 00 command: 0F F0 00 00 # name: VOL+ type: parsed protocol: NECext address: 86 05 00 00 command: 0C F3 00 00 # name: VOL- type: parsed protocol: NECext address: 86 05 00 00 command: 0D F2 00 00 # name: CH+ type: parsed protocol: NECext address: 86 05 00 00 command: 0A F5 00 00 # name: CH- type: parsed protocol: NECext address: 86 05 00 00 command: 0B F4 00 00 # name: MUTE type: parsed protocol: NECext address: 86 05 00 00 command: 0E F1 00 00 # name: POWER type: parsed protocol: NECext address: 02 7D 00 00 command: 46 B9 00 00 # name: MUTE type: parsed protocol: NECext address: 02 7D 00 00 command: 4C B3 00 00 # name: CH+ type: parsed protocol: NECext address: 02 7D 00 00 command: 0F F0 00 00 # name: CH- type: parsed protocol: NECext address: 02 7D 00 00 command: 5A A5 00 00 # name: VOL+ type: parsed protocol: NECext address: 02 7D 00 00 command: 0C F3 00 00 # name: VOL- type: parsed protocol: NECext address: 02 7D 00 00 command: 19 E6 00 00 # name: CH- type: parsed protocol: NECext address: 02 7D 00 00 command: 41 BE 00 00 # name: VOL- type: parsed protocol: NECext address: 02 7D 00 00 command: 42 BD 00 00 # name: CH- type: parsed protocol: NECext address: 02 7D 00 00 command: 57 A8 00 00 # name: VOL+ type: parsed protocol: NECext address: 02 7D 00 00 command: 15 EA 00 00 # name: POWER type: parsed protocol: NECext address: 84 E0 00 00 command: 20 DF 00 00 # name: CH+ type: parsed protocol: NECext address: 84 E0 00 00 command: 50 AF 00 00 # name: CH- type: parsed protocol: NECext address: 84 E0 00 00 command: 51 AE 00 00 # name: VOL+ type: parsed protocol: NECext address: 84 E0 00 00 command: 60 9F 00 00 # name: VOL- type: parsed protocol: NECext address: 84 E0 00 00 command: 61 9E 00 00 # name: MUTE type: parsed protocol: NECext address: 84 E0 00 00 command: 64 9B 00 00 # name: CH- type: parsed protocol: NECext address: 84 E0 00 00 command: 57 A8 00 00 # name: POWER type: parsed protocol: NEC address: 6E 00 00 00 command: 02 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 6E 00 00 00 command: 06 00 00 00 # name: VOL- type: parsed protocol: NEC address: 6E 00 00 00 command: 0C 00 00 00 # name: CH+ type: parsed protocol: NEC address: 6E 00 00 00 command: 08 00 00 00 # name: CH- type: parsed protocol: NEC address: 6E 00 00 00 command: 0E 00 00 00 # name: MUTE type: parsed protocol: NEC address: 6E 00 00 00 command: 04 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 04 00 00 00 command: 02 00 00 00 # name: VOL- type: parsed protocol: NEC address: 04 00 00 00 command: 03 00 00 00 # name: MUTE type: parsed protocol: NEC address: 04 00 00 00 command: 09 00 00 00 # name: CH+ type: parsed protocol: NEC address: 04 00 00 00 command: 00 00 00 00 # name: CH- type: parsed protocol: NEC address: 04 00 00 00 command: 01 00 00 00 # name: MUTE type: parsed protocol: NEC address: 50 00 00 00 command: 0B 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 50 00 00 00 command: 12 00 00 00 # name: VOL- type: parsed protocol: NEC address: 50 00 00 00 command: 15 00 00 00 # name: CH+ type: parsed protocol: NEC address: 50 00 00 00 command: 19 00 00 00 # name: CH- type: parsed protocol: NEC address: 50 00 00 00 command: 18 00 00 00 # name: POWER type: parsed protocol: NECext address: 85 7C 00 00 command: 80 7F 00 00 # name: VOL+ type: parsed protocol: NECext address: 85 7C 00 00 command: 8F 70 00 00 # name: VOL- type: parsed protocol: NECext address: 85 7C 00 00 command: 93 6C 00 00 # name: CH+ type: parsed protocol: NECext address: 85 7C 00 00 command: 8D 72 00 00 # name: CH- type: parsed protocol: NECext address: 85 7C 00 00 command: 91 6E 00 00 # name: MUTE type: parsed protocol: NECext address: 85 7C 00 00 command: 97 68 00 00 # name: CH- type: parsed protocol: NECext address: 85 7C 00 00 command: 96 69 00 00 # name: POWER type: parsed protocol: NECext address: EA C7 00 00 command: 17 E8 00 00 # name: VOL+ type: parsed protocol: NECext address: EA C7 00 00 command: 0F F0 00 00 # name: VOL- type: parsed protocol: NECext address: EA C7 00 00 command: 10 EF 00 00 # name: MUTE type: parsed protocol: NECext address: EA C7 00 00 command: 20 DF 00 00 # name: VOL+ type: parsed protocol: RC6 address: 00 00 00 00 command: 10 00 00 00 # name: VOL- type: parsed protocol: RC6 address: 00 00 00 00 command: 11 00 00 00 # name: CH+ type: parsed protocol: RC6 address: 00 00 00 00 command: 4C 00 00 00 # name: CH- type: parsed protocol: RC6 address: 00 00 00 00 command: 4D 00 00 00 # name: MUTE type: parsed protocol: RC6 address: 00 00 00 00 command: 0D 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 07 00 00 00 command: E0 00 00 00 # name: VOL- type: parsed protocol: Samsung32 address: 07 00 00 00 command: 23 00 00 00 # name: CH- type: parsed protocol: Samsung32 address: 07 00 00 00 command: 13 00 00 00 # name: POWER type: parsed protocol: Samsung32 address: 07 00 00 00 command: 98 00 00 00 # name: VOL+ type: parsed protocol: SIRC address: 01 00 00 00 command: 12 00 00 00 # name: VOL- type: parsed protocol: SIRC address: 01 00 00 00 command: 13 00 00 00 # name: CH+ type: parsed protocol: SIRC address: 01 00 00 00 command: 10 00 00 00 # name: CH- type: parsed protocol: SIRC address: 01 00 00 00 command: 11 00 00 00 # name: MUTE type: parsed protocol: SIRC address: 01 00 00 00 command: 14 00 00 00 # name: POWER type: parsed protocol: SIRC address: 01 00 00 00 command: 6D 00 00 00 # name: VOL- type: parsed protocol: SIRC address: 01 00 00 00 command: 73 00 00 00 # name: VOL+ type: parsed protocol: SIRC address: 01 00 00 00 command: 72 00 00 00 # name: CH- type: parsed protocol: SIRC15 address: 97 00 00 00 command: 3C 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 02 00 00 00 command: 1F 00 00 00 # name: VOL- type: parsed protocol: NEC address: 02 00 00 00 command: 1E 00 00 00 # name: MUTE type: parsed protocol: NEC address: 02 00 00 00 command: 1C 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 40 00 00 00 command: 1A 00 00 00 # name: VOL- type: parsed protocol: NEC address: 40 00 00 00 command: 1E 00 00 00 # name: MUTE type: parsed protocol: NEC address: 40 00 00 00 command: 10 00 00 00 # name: CH+ type: parsed protocol: NEC address: 40 00 00 00 command: 1B 00 00 00 # name: CH- type: parsed protocol: NEC address: 40 00 00 00 command: 1F 00 00 00 # name: CH- type: parsed protocol: NEC address: 04 00 00 00 command: 1A 00 00 00 # name: POWER type: parsed protocol: NEC address: 01 00 00 00 command: 10 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 01 00 00 00 command: 0E 00 00 00 # name: VOL- type: parsed protocol: NEC address: 01 00 00 00 command: 0F 00 00 00 # name: CH+ type: parsed protocol: NEC address: 01 00 00 00 command: 0C 00 00 00 # name: CH- type: parsed protocol: NEC address: 01 00 00 00 command: 0D 00 00 00 # name: MUTE type: parsed protocol: NEC address: 01 00 00 00 command: 17 00 00 00 # name: POWER type: parsed protocol: NEC address: 08 00 00 00 command: D7 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 08 00 00 00 command: 80 00 00 00 # name: VOL- type: parsed protocol: NEC address: 08 00 00 00 command: 8E 00 00 00 # name: CH+ type: parsed protocol: NEC address: 08 00 00 00 command: 83 00 00 00 # name: CH- type: parsed protocol: NEC address: 08 00 00 00 command: 86 00 00 00 # name: MUTE type: parsed protocol: NEC address: 08 00 00 00 command: DF 00 00 00 # name: POWER type: parsed protocol: RC5 address: 01 00 00 00 command: 0C 00 00 00 # name: MUTE type: parsed protocol: RC5 address: 01 00 00 00 command: 0D 00 00 00 # name: VOL+ type: parsed protocol: RC5 address: 01 00 00 00 command: 10 00 00 00 # name: VOL- type: parsed protocol: RC5 address: 01 00 00 00 command: 11 00 00 00 # name: CH+ type: parsed protocol: RC5 address: 01 00 00 00 command: 20 00 00 00 # name: CH- type: parsed protocol: RC5 address: 01 00 00 00 command: 21 00 00 00 # name: MUTE type: parsed protocol: NECext address: 00 7F 00 00 command: 50 AF 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 7F 00 00 command: 1E E1 00 00 # name: VOL- type: parsed protocol: NECext address: 00 7F 00 00 command: 5F A0 00 00 # name: CH+ type: parsed protocol: NECext address: 00 7F 00 00 command: 1F E0 00 00 # name: CH- type: parsed protocol: NECext address: 00 7F 00 00 command: 5C A3 00 00 # name: POWER type: parsed protocol: NECext address: 64 46 00 00 command: 5D A2 00 00 # name: CH+ type: parsed protocol: NECext address: 64 46 00 00 command: DE 21 00 00 # name: CH- type: parsed protocol: NECext address: 64 46 00 00 command: DB 24 00 00 # name: POWER type: parsed protocol: NEC address: 20 00 00 00 command: 52 00 00 00 # name: MUTE type: parsed protocol: NEC address: 20 00 00 00 command: 53 00 00 00 # name: CH+ type: parsed protocol: NEC address: 20 00 00 00 command: 02 00 00 00 # name: CH- type: parsed protocol: NEC address: 20 00 00 00 command: 09 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 20 00 00 00 command: 03 00 00 00 # name: VOL- type: parsed protocol: NEC address: 20 00 00 00 command: 41 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 BF 00 00 command: 0D F2 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 BF 00 00 command: 44 BB 00 00 # name: VOL- type: parsed protocol: NECext address: 00 BF 00 00 command: 43 BC 00 00 # name: MUTE type: parsed protocol: NECext address: 00 BF 00 00 command: 0E F1 00 00 # name: CH+ type: parsed protocol: NECext address: 00 BF 00 00 command: 4A B5 00 00 # name: CH- type: parsed protocol: NECext address: 00 BF 00 00 command: 4B B4 00 00 # name: POWER type: parsed protocol: RC5 address: 03 00 00 00 command: 0C 00 00 00 # name: VOL+ type: parsed protocol: RC5 address: 03 00 00 00 command: 10 00 00 00 # name: VOL- type: parsed protocol: RC5 address: 03 00 00 00 command: 11 00 00 00 # name: CH+ type: parsed protocol: RC5 address: 03 00 00 00 command: 20 00 00 00 # name: CH- type: parsed protocol: RC5 address: 03 00 00 00 command: 21 00 00 00 # name: MUTE type: parsed protocol: RC5 address: 03 00 00 00 command: 0D 00 00 00 # name: POWER type: parsed protocol: NECext address: 00 BF 00 00 command: 00 FF 00 00 # name: VOL+ type: parsed protocol: NECext address: 00 BF 00 00 command: 48 B7 00 00 # name: VOL- type: parsed protocol: NECext address: 00 BF 00 00 command: 49 B6 00 00 # name: MUTE type: parsed protocol: NECext address: 00 BF 00 00 command: 01 FE 00 00 # name: POWER type: parsed protocol: Samsung32 address: 17 00 00 00 command: 14 00 00 00 # name: CH- type: parsed protocol: Samsung32 address: 17 00 00 00 command: 11 00 00 00 # name: CH+ type: parsed protocol: Samsung32 address: 17 00 00 00 command: 10 00 00 00 # name: VOL- type: parsed protocol: Samsung32 address: 17 00 00 00 command: 13 00 00 00 # name: VOL+ type: parsed protocol: Samsung32 address: 17 00 00 00 command: 12 00 00 00 # name: MUTE type: parsed protocol: Samsung32 address: 17 00 00 00 command: 15 00 00 00 # name: POWER type: parsed protocol: RC5 address: 00 00 00 00 command: 0C 00 00 00 # name: CH+ type: parsed protocol: RC5X address: 00 00 00 00 command: 10 00 00 00 # name: CH- type: parsed protocol: RC5X address: 00 00 00 00 command: 11 00 00 00 # name: VOL+ type: parsed protocol: RC5X address: 00 00 00 00 command: 16 00 00 00 # name: VOL- type: parsed protocol: RC5X address: 00 00 00 00 command: 15 00 00 00 # name: MUTE type: parsed protocol: RC5 address: 00 00 00 00 command: 0D 00 00 00 # name: CH+ type: parsed protocol: RC6 address: 00 00 00 00 command: 20 00 00 00 # name: CH- type: parsed protocol: RC6 address: 00 00 00 00 command: 21 00 00 00 # name: POWER type: parsed protocol: NEC address: A0 00 00 00 command: 5F 00 00 00 # name: MUTE type: parsed protocol: NEC address: A0 00 00 00 command: 1C 00 00 00 # name: VOL+ type: parsed protocol: NEC address: A0 00 00 00 command: 40 00 00 00 # name: VOL- type: parsed protocol: NEC address: A0 00 00 00 command: 5D 00 00 00 # name: CH+ type: parsed protocol: NEC address: A0 00 00 00 command: 03 00 00 00 # name: CH- type: parsed protocol: NEC address: A0 00 00 00 command: 1F 00 00 00 # name: POWER type: parsed protocol: NEC address: 38 00 00 00 command: 12 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 38 00 00 00 command: 0E 00 00 00 # name: VOL- type: parsed protocol: NEC address: 38 00 00 00 command: 0F 00 00 00 # name: MUTE type: parsed protocol: NEC address: 38 00 00 00 command: 18 00 00 00 # name: CH+ type: parsed protocol: NEC address: 38 00 00 00 command: 0A 00 00 00 # name: CH- type: parsed protocol: NEC address: 38 00 00 00 command: 0B 00 00 00 # name: POWER type: parsed protocol: SIRC address: 01 00 00 00 command: 2E 00 00 00 # name: POWER type: parsed protocol: SIRC address: 01 00 00 00 command: 2F 00 00 00 # name: POWER type: parsed protocol: NECext address: EA C7 00 00 command: 97 68 00 00 # name: POWER type: parsed protocol: NECext address: 40 40 00 00 command: 0A F5 00 00 # name: VOL+ type: parsed protocol: NECext address: 40 40 00 00 command: 15 EA 00 00 # name: VOL- type: parsed protocol: NECext address: 40 40 00 00 command: 1C E3 00 00 # name: CH+ type: parsed protocol: NECext address: 40 40 00 00 command: 1F E0 00 00 # name: CH- type: parsed protocol: NECext address: 40 40 00 00 command: 1E E1 00 00 # name: MUTE type: parsed protocol: NECext address: 40 40 00 00 command: 0F F0 00 00 # name: MUTE type: parsed protocol: NEC address: 01 00 00 00 command: 41 00 00 00 # name: MUTE type: parsed protocol: NECext address: A0 B7 00 00 command: AF 50 00 00 # name: VOL+ type: parsed protocol: NECext address: AD ED 00 00 command: BA 45 00 00 # name: VOL- type: parsed protocol: NECext address: AD ED 00 00 command: BB 44 00 00 # name: CH+ type: parsed protocol: NECext address: AD ED 00 00 command: B0 4F 00 00 # name: CH- type: parsed protocol: NECext address: AD ED 00 00 command: B1 4E 00 00 # name: MUTE type: parsed protocol: NECext address: AD ED 00 00 command: C5 3A 00 00 # name: POWER type: parsed protocol: NEC address: 00 00 00 00 command: 1A 00 00 00 # name: VOL+ type: parsed protocol: NEC address: 00 00 00 00 command: 11 00 00 00 # name: VOL- type: parsed protocol: NEC address: 00 00 00 00 command: 33 00 00 00 #